this post was submitted on 26 Dec 2024
483 points (97.6% liked)

memes

10705 readers
2211 users here now

Community rules

1. Be civilNo trolling, bigotry or other insulting / annoying behaviour

2. No politicsThis is non-politics community. For political memes please go to !politicalmemes@lemmy.world

3. No recent repostsCheck for reposts when posting a meme, you can only repost after 1 month

4. No botsNo bots without the express approval of the mods or the admins

5. No Spam/AdsNo advertisements or spam. This is an instance rule and the only way to live.

Sister communities

founded 2 years ago
MODERATORS
 
you are viewing a single comment's thread
view the rest of the comments
[–] AA5B@lemmy.world 2 points 1 day ago* (last edited 1 day ago) (1 children)

Program it in increments?

My house has a lot of thermal mass. In the morning when the temperature comes up, it tends to overshoot and make the air temperature too hot after working hard to heat all that thermal mass. However I found it much more comfortable to add an increment: half an hour at a degree colder than I want. Now it can heat all that thermal mass while overheating the air is just playing into my hands

[–] chonglibloodsport@lemmy.world 4 points 1 day ago (1 children)

I’ve got it programmed in increments of a half a degree per hour. The thing still goes into panic mode.

[–] AA5B@lemmy.world 2 points 1 day ago (1 children)

I think they might be computing the derivative of the temperature at time t in real time. When the schedule shifts to a higher set point the derivative goes to positive infinity and the system panics and calls for emergency maximum heat output.

They really ought to compute the temperature set point schedule for the whole day at once and then apply a low pass filter to that.