Heat pumps are not simple at all. They are extremely efficient but can’t produce a large temperature gradient so they need to run very long cycles (potentially remaining on 24 hours straight). Modern cold weather air source heat pumps also tend to have variable output (variable speed compressor, variable speed fan). This demands a more complicated thermostat that adjusts the heat pump up and down, possibly with PWM.
And then there’s the emergency/auxiliary heating from the furnace. The thermostat needs to have some intelligent logic to decide when the heating demand exceeds the capacity of the heat pump and call for the furnace.