this post was submitted on 01 Nov 2024
903 points (98.7% liked)
memes
10163 readers
2659 users here now
Community rules
1. Be civil
No trolling, bigotry or other insulting / annoying behaviour
2. No politics
This is non-politics community. For political memes please go to !politicalmemes@lemmy.world
3. No recent reposts
Check for reposts when posting a meme, you can only repost after 1 month
4. No bots
No bots without the express approval of the mods or the admins
5. No Spam/Ads
No advertisements or spam. This is an instance rule and the only way to live.
Sister communities
- !tenforward@lemmy.world : Star Trek memes, chat and shitposts
- !lemmyshitpost@lemmy.world : Lemmy Shitposts, anything and everything goes.
- !linuxmemes@lemmy.world : Linux themed memes
- !comicstrips@lemmy.world : for those who love comic stories.
founded 1 year ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
view the rest of the comments
This happens with fire sprinklers a lot, one sprinkler goes off, and triggers the rest of the floor, or sometimes even building.
That's not how it works. Each sprinkler has it's own trigger mechanism, the glass bulb, and cannot trigger another sprinkler.
There are systems where this happens, but the sprinkler heads look very different, and you won't find them in an office building.
There are sprinklers where this happens and the sprinklers look exactly the same. There’s a pressure switch on the sprinkler line that activates a deluge pump. This pump has enough pressure and flow capacity to break open the glass ampules of the remaining sprinklers in the circuit.
Isn’t the water in sprinkler systems a stagnant mess too?
Yes. A combination of rust, thread cutting oil, and water that has been in the pipes often since the system was filled. It smells, it will stain anything it touches, and it's a smell that's difficult to remove.
Not true everywhere. Many buildings, especially industrial, require a flush of the fire suppression system annually or biannually to test that everything is still functional.
That's to test the incoming main, the actual grid on the floor doesn't get flushed. There's a lot of dead end pipes that can't be flushed.
Dry pipe systems are a thing. But not very common from my limited understanding.
Dry pipe systems are a thing. But not very common from my limited understanding.
Once I turned a suspicious faucet I shouldn't have and got a blast of this in the face.
This guy sprinkles
Also I've heard that the water that first comes out of those sprinklers is RANK from having sat in the pipes for years
It definitely is.
It has a particular smell that doesn't come out of fabric easily, either.
Theoretically the water hammer effect might be able to break that glass, but I think it's unlikely.
You get a water hammer when you shut off the flow, not when you open it.
I don't think water hammer would apply because there's no abrupt cutoff or change in direction of the flow.