this post was submitted on 01 Jun 2024
453 points (99.3% liked)
Photography
4518 readers
1 users here now
A community to post about photography:
We allow a wide range of topics here including; your own images, technical questions, gear talk, photography blogs etc. Please be respectful and don't spam.
founded 1 year ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
view the rest of the comments
Hi!
I’ve only ever managed to get the lide30 to play nice. I have destroyed one 110 and two 220-scanners in my efforts to build a more versatile rig.
What happens if you drop the prism back in?
I’ve also speculated about there being som calibration and automatic gain control going on in these newer models. I believe it could be used to normalize the values coming off of the individual sensor segments.
On my latest attempt at a 220 scanner, I actually built a small dimmable LED circuit that I attached externally to try and influence the calibration I thought was happening, but there was a disappointing lack of results. Come to think of it, I still have that rig laying around somewhere, and the experiment may have been flawed, I’ll have a look next time I’m at my workshop. I’ll let you know what I find.
I know that rig is at least functional, as objects placed directly onto the glass renders crude shadows on the scans.
That’s the long answer, the short answer is no, I don’t have any tips, maybe aside from working on fooling the possible calibration somehow.
I managed to change the image by just shining a torch into it during the calibration and the scan. This is exciting, I might be making progress :-)
Thats really Cool! Thanks for letting me know, this might be the impetus I needed to go back to working on the 220 camera!
So, when I say "change the image", I mean the torch does affect the calibration, in the sense that I get different patterns of stripes based on the position of the torch, but it's still just outputting stripes.
Here are two scans I made by waving the torch around randomly during the calibration, then resting the torch on the glass.
For some reason each pixel is just outputing the same brightness for the whole duration of the scan, except for that black spot where the torch is, which is weird.
So, I re-installed the prism, luckily it just slots back in. I'm not sure if it helped at all, I still get the much the same result most of the time.
I did manage to get this result. It's black at the top because the lid was closed. I opened the scanner half way thru, and the scan turned white. Then I waved the torch over the sensor and got a definite zigzag. And there's a hint of grey in the middle, which is encouraging.
So, the sensor is still working, it's responding to light, just not in a usable way.
Ok, thank you.